Parameter of the pin configuration

Input 1

- Trigger active high

- Trigger active low

Trigger signal is „high“ active  (at 1)

Trigger signal is „low“ active (at 0)

Input 2

- No Function

- Power

No function

In ECU-Mode: Signal has the function of the Power-Buttons.

Input 3

- No Function

- Sync-Impulse

No function

Synchronization impulse will be generated with rising slope.

Input 4

- Stream start high active

 

- Stream start low active

Signal has the function of the stream start button high active (at 1)

 

Signal has the function of stream start button low active (at 0)

Input 5

- No Function

No function

Input 6

- No Function

No function

Output 1

- Sample Signal

 

 

- Sample Pulse

 

- No Function

Signal has the function of start button of the measurement cycle as a constant signal (0/1.)

 

Signal has the function of the start button of the measurement cycle as an impulse signal.

 

No function

Output 2

- Digitize Current Signal

 

- Stream Signal

 

 

- Stream Pulse

 

 

- No Function

Gives the digital value of the current signal.

 

Creates a logical 1, when stream data package is sent in sensor simulation mode

 

Create an impulse at the beginning of sending a stream data package.

 

No function

Output 3

- Current Comperator

- Digital Trigger

 

 

- No Function

Hardware comperator for compensation of jitter.

 

Creates an impulse when a trigger event has occurred.

 

No function

Output 4

- Sync Signal

 

 

 

- Analog Trigger

 

- No Function

In ECU mode: synchronization impulse is sent as a digital signal.

 

In ECU mode: synchronization impulse is sent as an analog signal.

 

No function

 

Output 5

- No Function

No function

Output 6

- No Function

No function

Trigger Pulse

- Active high

 

 

 

- Active low

Definition of the impulse, created by trigger:
 - high active - (1)

 

Definition of the impulse, created by trigger:

 - low active - (0)

Sample Pulse

- Active high

 

 

 

- Active low

Definition of impulse, create by start/end of the measurement cycle - high active - (1)

 

Definition of impulse, create by start/end of the measurement cycle - high active - (0))

Stream Pulse

- Active high

 

 

 

- Active low

Definition of the impulse, created by start/end of stream data package - high active - (1)

 

Definition of the impulse, created by start/end of stream data package - high active - (0)

DAC 1

- Signal 1

- No Function

Data signal of 1. sensor

DAC 2

- Signal 2

- No Function

Data signal of 2. sensor

DAC 3

- Signal 3

- No Function

Data signal of 3. sensor

DAC 4

- Signal 4

- No Function

Data signal of 4. sensor